GC

GC-4000A Gas Chromatograph

GC-4000A Series is well suited for analyzing of a wide range of chemicals as gases, liquids or gas-liquid mixtures with boiling points less than 400℃. This versatile instrument can be used in industries such as the oil, coal mining, chemical, environmental protection, textile, agricultural, medicinal, and sanitation industry.

Technical Specifications

TCD  

FID

ECD

FPD

NPD

Sensitivity

S≥5000
mv.ml/mg (benzene)

  

Minimum Detectable Quantity 

M≤1×10-11
g/sec
(hexadecane)

M ≤1×10-13
g/ml(r-666)

Mp≤2×10-12
g/s(1605)
Ms≤5×10
-11
g/s( thiophene )

MN≤5×10-13
g/s
Mp≤1×10-12
g/s

Noise

≤0.1mv

≤5×0-14A

≤0.01mv

≤2×10-12A

≤2×10-13A

Linear Dynamic Range 

106

103

103

103

Drift

1×10-14
A/30min

0.02mv/30min

3×10-13
A/30min

2.5×10-12 A/h

 

1. We offer five types of detectors. Each one is specifically designed to fit your needs.

√ Flame Ionization Detector (FID): Used for analyzing organic compound requiring high sensitivity.
√ Thermal Conductivity Detector (TCD): Used for analyzing ambient temperature gases, water, and small hydrocarbon compounds.
√ Flame Photometric Detector (FPD): Used for analyzing sulfurous or phosphorous compounds.
√ Electron Capture Detector (ECD): Used for detecting pesticides or chlorides through Electron Capture
√ Nitrogen-Phosphorus Detector (NPD): Used for trace analysis of nitrides or phosphides    

2. Easy installion and maintence
3. Large column oven that be simultaneously installed with three columns.
4. Efficient design. Instrument can be installed with up to three types of detectors at once, three independent electrical circuit systems and three signal outputs.
5. Flexible packed column and capillary column system.
6. Stable temperature control system: Temperature programming of up to 8 ramps; individually controlled temperatures for each sample injector and detector; Multiple sensors to prevent over-heating.
7. Improved pressure stabilization and multiple gas path systems: a single, dual or triple gas path; Injector and valve sample injection system; Back flushing and pre-cutting devices; Methane conversion oven.

 

Our Complete Set 

• Main unit
• Data processing workstation: a PC (optional), a printer (optional), workstation software and interface board
• Gas sources/generators: air, hydrogen gas and high purity nitrogen gas (optional)
• Chromatographic column(s) (please specify)
• Spare parts

 

The following generators can be chosen for GC:
GH-200(G-101) High purity hydrogen generator
GH-100(G-101A) High purity hydrogen generator
GA-100(G-103) High purity air generator

GC Model ve Özellikler Tablosu

Model

Usage

Features/Configuration

GC-4001A

Gas and liquid analysis

Instrument and thermal conductance

GC-4002A

General

Instrument, single hydrogen flame detector and 8 ramp programmable heating

GC-4003A

General

Instrument, double hydrogen flame detector, 8 ramp programmable heating and double gas paths.

GC-4004A

General

Instrument, single hydrogen flame, thermal conductance detector and 8 ramp programmable heating.

GC-4005A

General

Instrument, double hydrogen flame, thermal conductance detector, 8 ramp programmable heating and three gas paths.

GC-4006A

Natural gases

automatic analysis

Instrument, double hydrogen flame, thermal conductance detector, column for special purpose, capillary device, one-time automatic sample injection, 8 ramp programmable heating and three sets 6-way valve.

GC-4006B

Oil, all natural gases analysis

Instrument, hydrogen flame, thermal conductance detector, three columns for special purpose, capillary device, automatic reverse-blow system and 8 ramp programmable heating.

GC-4006C

Oil, all natural gases analysis

Instrument, hydrogen flame, thermal conductance detector, three columns for special purpose, 8 ramp programmable heating, capillary device, three gas paths and 6 – way valve.

GC-4006D

Analyzes dry gas, cracking gas, etc.

Instrument, thermal conductance detector, two packed column, switch system of gas carrier and 6-way valve.

GC-4006E

Analyzes benzene and tolune in petroleum

Instrument, thermal conductance detector, main and auxiliary columns, automatic reverse-blow system, imported high temperature automatic 6-way valve.

GC-4006F

Analyzes ether and alcohol

Instrument, hydrogen flame detector, main and auxiliary columns, imported 6-way valve, pre-incision and reverse blow device.

GC-4007A

Analyzes transformer oil

Instrument, hydrogen flame, thermal conductance detector, reforming furnace, 2 pieces of columns for special purpose, 8-ramp programmable heating, double gas path. thermal conductance detector,

GC-4008A

Coal Mining GC

Instrument, double hydrogen flame, reforming furnace, 2 pieces of columns for special purpose, 8-ramp programmable heating, three gas paths and 3 sets of 6-way valve.

GC-4008B

Coal Mining GC

Instrument, double hydrogen flame, thermal conductance detector, reforming furnace, 4 pieces of columns for special purpose, 8-ramp programmable heating, 4 gas paths. and 4 sets of 6-way valve.

GC-4009A

Environmental monitor, sanitation epidemic prevention and food check and measure

Instrument, hydrogen flame, ECD, 8 ramp programmable heating and 2 gas paths.

GC-4010A

Environmental monitor, sanitation epidemic prevention and food check and measure

Instrument, hydrogen flame, flame luminosity detector, 8 ramp programmable heating and 2 gas paths.

GC-4011A

Environmental monitor, sanitation epidemic prevention and food check and measure

Instrument, hydrogen flame, 、 ECD, flame luminosity detector, 8 ramp programmable heating and 3 gas paths.

GC-4012A

Check and measure the organic chlorine and others

Instrument, ECD, and 8 ramp programmable heating .

GC-4013A

Check and measure the organic phosphor

Instrument, nitrogen and phosphorus detector and 8 ramp programmable heating.

GC-4014A

General

Instrument, hydrogen flame, nitrogen and phosphorus detector, 8 ramp programmable heating and 2 gas paths

GC-4015A

Environmental monitor, sanitation epidemic prevention and food check and measure

Instrument, thermal conductance detector, nitrogen and phosphorus detector, 8 ramp programmable heating and 2 gas paths.

GC-4016A

Environmental monitor, sanitation epidemic prevention and food check and measure

Instrument, ECD, flame luminosity , nitrogen and phosphorus detector, 8 ramp programmable heating and 3 gas paths

GC-4017A

General

Instrument, hydrogen flame, ECD, nitrogen and phosphorus detector, 8 ramp programmable heating and 3 gas paths

GC-4018A

Analysis on e lectronegative organic and organic phosphor

Instrument, ECD, nitrogen and phosphorus detector, 8 ramp programmable heating and 2 gas path, 8 ramp programmable heating and 3 gas paths.

GC-4019A

General

Instrument, thermal conductance, hydrogen flame, ECD,

GC-4020A

Analysis on organic sulfur and other organic substance

Instrument, flame luminosity detector and 8 ramp programmable heating .

GC-4021A

General

Instrument, double hydrogen flame, flame luminosity detector, 8 ramp programmable heating and 3 gas paths.

GC-4022A

Analysis on routine gas, liquid

Instrument, thermal conductance, ECD, 8 ramp programmable heating and 2 gas paths.

electronegative substances

GC-4023A

General

Instrument, thermal conductance, double hydrogen flame, ECD, 8 ramp programmable heating and 3 gas paths.

GC-4024A

Analysis on organic sulfur, and electronegative substances

Instrument, flame luminosity, ECD, 8 ramp programmable heating and 2 gas paths

GC-4025A

Gas, non-condensed liquid analysis

Instrument, double thermal conductance detector, 8 ramp programmable heating and 2 gas paths.

GC-4026A

General

Instrument, hydrogen flame, flame luminosity, nitrogen and phosphorus detector, 8 ramp programmable heating and 3 gas paths.

GC-4027A

Analysis on o rganic phosphor, and organic sulfur

Instrument, flame luminosity, nitrogen and phosphorus detector, 8 ramp programmable heating and 3 gas paths.

GC-4028A

Indoor air monitoring

Instrument, hydrogen flame, detector, 8 ramp programmable heating, thermal desorption device and capillary device.

GC-4029A

Indoor air monitoring

Instrument, double thermal conductance detector, 8 ramp programmable heating, thermal desorption device and capillary device.

GC-4030A

Indoor air monitoring

Instrument, thermal conductance, nitrogen and phosphorus detector, 8 ramp programmable heating, thermal desorption device and capillary device.

GC-4031A

General

Instrument, double hydrogen flame, ECD, 8 ramp programmable heating and 3gas paths.

GC-4032A

Analysis on routine gas, liquid

Instrument, thermal conductance, flame luminosity, detector, 8 ramp programmable heating and 2 gas paths.
organic phosphor

GC-4033A

Analysis on routine gas

Instrument, double hydrogen flame detector, reforming furnace, 3 sets of 6-way valve, 8 ramp programmable heating and 3 gas paths.

GC-4034A

Atom and routine gas analysis

Instrument, hydrogen flame, thermal conductance detector, reforming furnace, 2 sets of 6-way valve, 8 ramp programmable heating and 3 gas paths.